The method as specified is for "Ionograph" results which the equipment is
programmed to report. Using Ion Chromatography can give you the same results.
Once you calculate the ug/cm sq for Cl ion mutiply the result by MW of NaCl
(58.5)and diviude by atomic wt of Cl (35.5). This should give equivalent NaCl
per cm sq.
Note the Ionograph does not differentiate between the different Halogen anions
and it may be necessary to convery F, and Br results along the same lines.

George Milad