Ladies & Gentlemen:
I am trying to initiate test IPC-TM-650 in my wave solder machine to
test for the presence of halides in a "halide-free" no clean flux. I have
had issues with cross contamination of water soluble and no clean flux due
to operator error (ie. the operator accidentally dumps water soluble flux
into a no clean flux bath). IPC-TM-650 calls for the use of silver
chromate test paper. Does anybody know where I can get some of this paper?
Anybody have any ideas on how to prevent cross contamination of fluxes
-Thanks,
Teo Tijerina
################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe: SUBSCRIBE TechNet <your full name>
To unsubscribe: SIGNOFF TechNet
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################