     Address,

     I have a PCA that was once routed using a phenolic base (Jig).  The
     base and Router are no longer available.  The fix is to score the
     panels prior to assembling.

     The immediate need is, "How do I depanel existing PCAs?"  Again, the
     panels have NOT been scored and the router/base are not available. Is
     it possible to score the PCA with components loaded?  I could then use
     a depanelizer such as CAB.  Alternatively, could I use a skip Router
     for depaneling PCAs?

     This is a .028, std. 1 x 4 array, PCMCIA application.  Any advice as
     well as service bureaus to perform any of the above or any other
     suggestions.  Preferably someone local to Dallas, TX.

     John Gulley

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################