I think you are is missing the point (although [log in to unmask] is the only one that can say) To me he seems to be asking how he should create the library part. The answer to that is, IT DON'T MATTER. It can be rotated any which way in most every CAD system I know of when it's placed on the board. THEN assembly and fabrication rules apply. But not in library part creation.
How 'bout it [log in to unmask] , you're a librarian, right?
George Uptain - Schlumberger Oilfield Services
Austin, Texas
[log in to unmask] (512)331-3183
-----Original Message-----
From: Olson, Jack C [mailto:[log in to unmask]]
Sent: Tuesday, September 22, 1998 11:14 AM
To: [log in to unmask]
Subject: Re: [DC] PCB Footprint standard for smt polarised components?
I would like to know which standard that is, that you are referring to. Most
reels of components that I have seen, the polarity is on the left at zero
rotation. On a related topic, IC's in sticks have pin 1 to the upper left,
and IC's on reels have pin 1 lower left, everything I have seen is always on
the left, or have I lost my mind? (don't have any reels here)
Onward thru the fog, Jack
-----Original Message-----
From: Barry Olney [SMTP:[log in to unmask]]
Sent: Monday, September 21, 1998 5:55 PM
To: [log in to unmask]
Subject: Re: [DC] PCB Footprint standard for smt polarised
components?
Hi Paul,
According to the Jedec standard:
The component should be drawn parallel to the X axis
The polarisation marking and Pin 1 to the right.
Cheers,
Barry Olney
Paul Arklay wrote:
>
> Hi Everyone,
>
> When creating smt polarised component geometries on your cad
system for pcb
> design do you create them horizontally with the polarised side to
the right
> or the left? In other words is there a standard for this when
creating
> PCB footprints?
>
> Best Regards,
> Paul Arklay
>
> Jtec Pty Limited
> Unit 3
> 118-122 Bowden Street
> Meadowbank NSW 2114
> Sydney Australia
>
> Switch +61 2 98096933
> Fax +61 2 93640055
> Direct +61 2 93900622
>
> [log in to unmask]
>
> ################################################################
> DesignerCouncil E-Mail Forum provided as a free service by IPC
using LISTSERV 1.8c
> ################################################################
> To subscribe/unsubscribe, send a message to [log in to unmask] with
following text in the body:
> To subscribe: SUBSCRIBE DesignerCouncil <your full name>
> To unsubscribe: SIGNOFF DesignerCouncil
> ################################################################
> Please visit IPC's web site (http://www.ipc.org) "On-Line
Services" section for additional information.
> For technical support contact Hugo Scaramuzza at [log in to unmask] or
847-509-9700 ext.312
> ################################################################
--
__________________________________________________________________
Barry Olney http://www.icd.com.au
Managing Director
In-Circuit Design Pty Ltd
VeriBest Solutions Centre
Level 1, Princess Tower PO Box 362, Robina Business Centre
1 Princess Street, Unit 34/24 Ron Penhaligon Way,
Kew, VIC 3101, Australia Robina, Qld 4226, Australia
Ph: +61 3 9205 9595 Ph: +61 7 5562 0075
Fax:+61 3 9205 9410 Fax: +61 7 5562 1175
Mbl:+61 4 1117 0827 Email: [log in to unmask]
__________________________________________________________________
################################################################
DesignerCouncil E-Mail Forum provided as a free service by IPC using
LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with
following text in the body:
To subscribe: SUBSCRIBE DesignerCouncil <your full name>
To unsubscribe: SIGNOFF DesignerCouncil
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services"
section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or
847-509-9700 ext.312
################################################################
################################################################
DesignerCouncil E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe: SUBSCRIBE DesignerCouncil <your full name>
To unsubscribe: SIGNOFF DesignerCouncil
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################
################################################################
DesignerCouncil E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe: SUBSCRIBE DesignerCouncil <your full name>
To unsubscribe: SIGNOFF DesignerCouncil
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################
|