Hi Jared,
The camelot converter does not recognize fiducials within the main program
body. If you go to the hard drive of your on board computer ,you will see
that a typical program comprises of a main file plus two additional files
for fiducials. I don't remember the file extension (it's been a year!), but
the machine creates it's own vision files after the teaching process is
completed. The machine and software have been designed to perform so.
The correct way, is to delete the fiducial information from the transfer
program file. Load the program into camelot. Open the program. Insert
fiducial points by the insert and teach process. and then save the program.
Hope this helps


Nasir