If the cover is about 8 x 10 inches, probably a 1 or 2 inch hole would still
provide adequate shielding (just my opinion).

You might find more information on the Arizona ESD Assoc. website
(www.esdres.com/azesd) or at their upcoming conference and vendor fair
(free!) on July 22 at the Mesa Community Ctr., 201 N. Center St., Mesa, AZ.
 - tel. 602-357-2460.  (Maybe you could present your question to their
experts during one of the ESD panel discussions.)

Good Luck!
Jim Chilcote, Honeywell


 -----Original Message-----
From:     [log in to unmask]
Sent:     Friday, July 17, 1998 3:09 PM
To:  [log in to unmask]
Subject:  [TN] ESD Faraday shielding

Technetters, please help.

I am studying a lid design for an ESD container to provide a
Faraday shield for printed wiring assemblies.  There needs to be
a hole or notch in the conductive lid so that it can be grasped
and removed.  What are the guidelines for the maximum size of
the hole so that adequate shielding is maintained?

If you don't have an answer or opinion, are there recommended
container suppliers, organizations, or other sources that could
also be contacted for advice?

Thanks in advance for any help.

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following
 text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section
 for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or
 847-509-9700 ext.312
################################################################

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################


ATOM RSS1 RSS2