Folks:
        I have heard the figure, 30 grams of component mass  per square inch
of pad area.

Joe H.

> -----Original Message-----
> From: sahmad [SMTP:[log in to unmask]]
> Sent: Wednesday, July 08, 1998 4:29 PM
> To:   [log in to unmask]
> Subject:      Re: [TN] ASSY: BGA sanity check
>
> Jim,
> Should the weight of the part on the bottom side of the board not be less
> than the retaining force generated by the surface tension of the molten
> solder for it not to fall off the board? Did any of the parts you used
> violate this criterion?
> Thanks.
> Syed.
>
>         -----Original Message-----
>         From:   Fulton Feng [SMTP:[log in to unmask]]
>         Sent:   Wednesday, July 01, 1998 5:24 PM
>         To:     [log in to unmask]
>         Subject:        Re: [TN] ASSY: BGA sanity check
>
>         FYI
>
>         > -----Original Message-----
>         > From: Maguire, James F [SMTP:[log in to unmask]]
>         > Sent: Wednesday, July 01, 1998 8:31 AM
>         > To:   [log in to unmask]
>         > Subject:      Re: [TN] ASSY: BGA sanity check
>         >
>         > Jerry,
>         >
>         > We recently did some testing of "double sided reflow" related to
>         > reliability. In our testing we were wondering if reflowing a 2nd
> time
>         > with the part on the "bottom" of the PWB (so gravity pulls the
> part away
>         > from the PWB surface) would impact reliability (and also, if it
> would
>         > stay in place during reflow).
>         >
>         > Our results showed a) it stayed in place and b) no impact on
> reliability
>         > (we've passed >1600 cycles -55/125C thermal shock with 30 min.
> dwells at
>         > temp per side without any electrical intermittents.
>         >
>         > Jim
>         > ================================================
>         > James F Maguire
>         > Associate Technical Fellow
>         > Boeing
>         >  Information, Space & Defense Systems - Phantom Works
>         > phone  (253)657-9063
>         > fax         (253)657-8903
>         > pager   (206)982-3737
>         > email     [log in to unmask]
>         > =================================================
>         >
>         > > ----------
>         > > From:         Jerry Cupples[SMTP:[log in to unmask]]
>         > > Reply To:     TechNet E-Mail Forum.;Jerry Cupples
>         > > Sent:         Tuesday, June 23, 1998 3:15 PM
>         > > To:   [log in to unmask]
>         > > Subject:      [TN] ASSY: BGA sanity check
>         > >
>         > > Hello, TechNet....
>         > >
>         > > Soldering (inline convection furnace) BGA's on both sides of a
> board
>         > > is
>         > > beyond my own experience, but it seems to violate a principle
> (at
>         > > least an
>         > > imaginary one) related to the controlled collapse, or perhaps
> liquids
>         > > under
>         > > tension.
>         > >
>         > > For a board design using 3 commercial BGA packages (PBGA 256,
> eutectic
>         > > balls on 1.27 mm pitch), am I obstinately blocking the path of
>         > > progress by
>         > > requesting that this package style be confined to only one
> surface of
>         > > a new
>         > > board design?
>         > >
>         > > If you are doing this today and it is a piece of cake, go
> ahead
> and
>         > > brag;
>         > > but I would prefer to hear that caution is well advised, i.e.
> tales of
>         > > misery, shame and corporate disaster resulting from such
> mistakes. ;-)
>         > >
>         > >
>         > > cheers,
>         > >
>         > >
>         > >
>         > >
>         > > Jerry Cupples
>         > > Interphase Corporation
>         > > Dallas, TX USA
>         > > http://www.iphase.com
>         > >
>         > >
> ################################################################
>         > > TechNet E-Mail Forum provided as a free service by IPC using
> LISTSERV
>         > > 1.8c
>         > >
> ################################################################
>         > > To subscribe/unsubscribe, send a message to [log in to unmask]
> with
>         > > following text in the body:
>         > > To subscribe:   SUBSCRIBE TechNet <your full name>
>         > > To unsubscribe:   SIGNOFF TechNet
>         > >
> ################################################################
>         > > Please visit IPC web site (http://jefry.ipc.org/forum.htm) for
>         > > additional information.
>         > > For technical support contact Hugo Scaramuzza at
> [log in to unmask]
> or
>         > > 847-509-9700 ext.312
>         > >
> ################################################################
>         > >
>         >
>         > ################################################################
>         > TechNet E-Mail Forum provided as a free service by IPC using
> LISTSERV 1.8c
>         > ################################################################
>         > To subscribe/unsubscribe, send a message to [log in to unmask]
> with
>         > following text in the body:
>         > To subscribe:   SUBSCRIBE TechNet <your full name>
>         > To unsubscribe:   SIGNOFF TechNet
>         > ################################################################
>         > Please visit IPC's web site (http://www.ipc.org) "On-Line
> Services"
>         > section for additional information.
>         > For technical support contact Hugo Scaramuzza at [log in to unmask]
> or
>         > 847-509-9700 ext.312
>         > ################################################################
>
>         ################################################################
>         TechNet E-Mail Forum provided as a free service by IPC using
> LISTSERV 1.8c
>         ################################################################
>         To subscribe/unsubscribe, send a message to [log in to unmask] with
> following text in the body:
>         To subscribe:   SUBSCRIBE TechNet <your full name>
>         To unsubscribe:   SIGNOFF TechNet
>         ################################################################
>         Please visit IPC's web site (http://www.ipc.org) "On-Line
> Services"
> section for additional information.
>         For technical support contact Hugo Scaramuzza at [log in to unmask] or
> 847-509-9700 ext.312
>         ################################################################
>
> ################################################################
> TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
> ################################################################
> To subscribe/unsubscribe, send a message to [log in to unmask] with
> following text in the body:
> To subscribe:   SUBSCRIBE TechNet <your full name>
> To unsubscribe:   SIGNOFF TechNet
> ################################################################
> Please visit IPC's web site (http://www.ipc.org) "On-Line Services"
> section for additional information.
> For technical support contact Hugo Scaramuzza at [log in to unmask] or
> 847-509-9700 ext.312
> ################################################################

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################


ATOM RSS1 RSS2