Mark Simmons <[log in to unmask]>
Reply To:
Date:
Fri, 10 Jul 1998 15:23:32 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (22 lines)
Matt, non wetting of a pad or land after HASL is very possible.  My
guess is the large areas had exposed CU on reciept.  In the areas around
the annular ring, may be a little Solder mask "bleed-out" or other
Solder mask related issue.  The chances of somethin chompin it off
during component attachment is slim.

Hope this helps,

Mark Simmons

################################################################