1. Other specifications MIL-I-46058c, IPC CC830 and IEC1086 but remember
these are test specifications not application. I do not know of an
application standard.
We do have application sheets covering dip, spray and brush, if you send be
your address I have them sent to you.
2. Bubbles in solvent based coatings is normally due to solvent entrapment
caused by a coating thickness greater then 0.003", you should withdrawal at
2" to 3" per minute, this is best done with automatic equipment.
3. Contact Don Hague at W.M. Hague on 781-275-8400 who should be able to
help with a small dipping system and air drying system.
Best Regards
David Greenman