Hi Paul,
Hi Paul,
I'm sorry but I don't quite understand what you mean about the single sided
glass exposure frame.  The flexible membrane of our exposure machine has a
thin glass frame on top of it as well as a thick glass frame where we lay
our films.  Is this the same?

Anyway, thanks a lot for the suggestion.  This is the first time I've heard
of this and it might just be what I'm looking for.

Marco Biagtan
NEC Components Phils. Inc.
Process Engineer

Paul Gould wrote:

> Marco,
> Just had another thought if it is only your contacts. If you are using a
> single sided glass exposure frame with a flexible membrane over the top,
> your copy film will be in contact with the membrane and will tend to get
> mechanically stretched. This would result in an apparent shrinkage after
> exposure. If this is a possibility, put a sheet of black card on top of
> the film before closing the lid and pulling the vacuum.
> Hope this helps.
> Paul Gould
> [log in to unmask]
> Teknacron Circuits Ltd
> Fax: 1983 865141
> Tel: 1983 866531
>
> ################################################################
> TechNet E-Mail Forum provided as a free service by IPC using LISTSERV
1.8c
> ################################################################
> To subscribe/unsubscribe, send a message to [log in to unmask] with
following text in the body:
> To subscribe:   SUBSCRIBE TechNet <your full name>
> To unsubscribe:   SIGNOFF TechNet
> ################################################################
> Please visit IPC web site (http://jefry.ipc.org/forum.htm) for additional
information.
> For technical support contact Hugo Scaramuzza at [log in to unmask] or
847-509-9700 ext.312
> ################################################################

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC web site (http://jefry.ipc.org/forum.htm) for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################


ATOM RSS1 RSS2