Marco, make sure your raw film sits at 70 degrees and 50% out of the
plastic bag
for 24 hours before you image and process it.  Then make sure it sits at
70/50 for a
couple of hours before you measure.  If you still see a problem, change
your dryer
temperature.  The old rule is "Overdrying makes oversize."

> -----Original Message-----
> From: Marco Biagtan [SMTP:[log in to unmask]]
> Sent: Wednesday, May 20, 1998 11:13 PM
> To:   [log in to unmask]
> Subject:      [TN] Photo tool stability
>
> Hi Guys,
>
> I have a problem with dimensional stability of photo tools.  The photo
> tools shrink after processing.  I've tried increasing the drying
> temperature (50-55C) just so it will not shrink but it still does.
> This is
> really giving me a headache.  Any suggestions?
>
>
>

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC web site (http://jefry.ipc.org/forum.htm) for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################


ATOM RSS1 RSS2