Folks.

We have had a load of assembled PCB's in from a new supplier.
trouble is they are not to drawing and i'm being asked if we can accept them. The problem is that
we have a flying lead connected to two through hole pillars. The drawing requires a 270 degree hook
on the wire before it is soldered to the post. The subbies have soldered the wire parallel to the post (straight up and down)

Question: is this as good as the requested hook method
        :will there be reliability problems in the future
        :would vibration /shock tests be required to prove the deviation is acceptable
        :should we just reurn to the subbie for correctio ;to drawing'

any help 'donations' gratefully accepted


Regards
Ian Squires
Senior Production Engineer
-------------------------------------------------------

Graseby Dynamics Ltd
Park Avenue, Bushey, Watford, Herts, WD2 2BW
Web Site: www.gradyn.co.uk
Phone:    01923-228566 xt 295
Fax:      01923-221361
E-mail:   [log in to unmask]

Registered in England no. 480992
Registered office:
765 Finchley Road, London, NW11 8DS
-------------------------------------------------------

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC web site (http://jefry.ipc.org/forum.htm) for additional information.
For the technical support contact Dmitriy Sklyar at [log in to unmask] or 847-509-9700 ext.311
################################################################


ATOM RSS1 RSS2