TECHNET Archives

May 1998

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Reply To:
TechNet E-Mail Forum.
Date:
Fri, 29 May 1998 00:31:10 EDT
Content-Type:
text/plain
Parts/Attachments:
text/plain (28 lines)
Valerie,

If the application is high frequency, then your customer may be more
interested in the plating material.  As signal frequency increases, the signal
concentrates less and less in the center of the conductor and moves to the
surface of the conductor.  The amount of penetration in to the conductor is
called the skin depth and is a function of frequency,  permeability of the
conductor, and resistivity of the conductor.

To sum it up, at high enough frequencies, the plating may become the dominant
conductor.

Good luck,

Frank

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC web site (http://jefry.ipc.org/forum.htm) for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################