Did you check to ensure that the vibrating mechanism in your Electroless Copper
line is mechanically sound?

N.Nelson
Dell Computer

We are experiencing a problem with voids. The void issue tends to be
on one end of the panel only, this end of the panel is towards the
bottom of the electrolytic copper tank when plated. Voids have
occurred on 4 different jobs all cuposited and plated on the same
day, but not all the panels had voids and other orders went thru
without voids. All chemistries were analyzed and found to be in spec.
During this time period we believe that the void issues are
mechanical. Low temp in cuposit or poor re-circulation due to pump
problems. Any suggestions on what other items should be checked?


Michael Dodson
Product Engineer
SBC Inc.

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text
 in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet
################################################################
Please visit IPC web site (http://jefry.ipc.org/forum.htm) for additional inform
ation.
For the technical support contact Dmitriy Sklyar at [log in to unmask] or 847-509-97
00 ext.311
################################################################

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC web site (http://jefry.ipc.org/forum.htm) for additional information.
For the technical support contact Dmitriy Sklyar at [log in to unmask] or 847-509-9700 ext.311
################################################################


ATOM RSS1 RSS2