For medical usesge the resistance will be specified with ranges up to
1x10E6.
This reflects the NFPA 99 hospital specification. For electronics
applications a range of 1x10E6 to 1x10E9 has been identified as the range
required for electrical safety. This information is in the ESD Association
Advisory Handbook ESD ADV-2.0-1994. The ESD Association is the ANSI
designated developer of ESD standards.
Al Cash
> ----------
> From: David Paluck[SMTP:[log in to unmask]]
> Reply To: TechNet E-Mail Forum.;David Paluck
> Sent: Tuesday, April 07, 1998 4:32 PM
> To: [log in to unmask]
> Subject: [TN] ESD Flooring
>
> What is the recommended resistance or resistivity of dissipative flooring
> for electronic assembly? Is there an IPC standard that specifies this?
>
> Thanks,
> David Paluck
> Electronic Systems, Inc.
>
> ################################################################
> TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
> ################################################################
> To subscribe/unsubscribe, send a message to [log in to unmask] with
> following text in the body:
> To subscribe: SUBSCRIBE TechNet <your full name>
> To unsubscribe: SIGNOFF TechNet
> ################################################################
> Please visit IPC web site (http://jefry.ipc.org/forum.htm) for additional
> information.
> For the technical support contact Dmitriy Sklyar at [log in to unmask] or
> 847-509-9700 ext.311
> ################################################################
>
################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe: SUBSCRIBE TechNet <your full name>
To unsubscribe: SIGNOFF TechNet
################################################################
Please visit IPC web site (http://jefry.ipc.org/forum.htm) for additional information.
For the technical support contact Dmitriy Sklyar at [log in to unmask] or 847-509-9700 ext.311
################################################################
|
|
|