notes for electrical testing:
1) see IPC-D-325A, page 52, note 23. ALSO SEE IPC-ET-652 FOR GUIDELINES.
2) we use the following note:
ELECTRICAL TESTING PER IPC-6012:
A. NET LIST TESTING USING THE SUPPLIED IPC-D-356 DATA IS REQD.
B. APPROX SMT LAND COUNT IS ___ ON PRIMARY SIDE, AND ___ ON SECONDARY SIDE.
THE MINIMUM PITCH IS ___.
C. TEST POINTS ARE ___ DIA LANDS ON LAYER ___.
D. MAXIMUM RATED VOLTAGE: ___ VDC.
Hope this helps.
Clifford H. Lamson phone: 407-727-5158
Designer 3 / CADD Group Leader pager: 407-690-8594
Harris G.A.S.D., MS22/4842 fax: 407-727-4430
P.O. Box 94000 email: [log in to unmask]