TECHNET Archives

March 1998

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Brant R. McClelland" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Thu, 26 Mar 1998 13:25:03 -0600
Content-Type:
text/plain
Parts/Attachments:
text/plain (68 lines)
Anthony,
   Note that this applies to smt devices only. Pin-in-hole (thru-hole)
placement
machines still use the pin 1 location as the part origin.

Regards,
Brant McClelland
Design Center,
Solectron Texas
[log in to unmask]



> ----------
> From:         SteveZeva[SMTP:[log in to unmask]]
> Reply To:     TechNet E-Mail Forum.;SteveZeva
> Sent:         Thursday, March 26, 1998 12:28 PM
> To:   [log in to unmask]
> Subject:      Re: [TN] Land Pattern and Component Modeling
>
> Hi Anthony,
>
>       I've don't know the exact reasoning behind it, but in all the gerber
> files I've seen, the component coordinates are to pin-1. If the design
> file
> had the coordinates go to the centroid, I know there would be a lot of
> "happy
> campers" out there! That would save another complete operation generating
> a
> CAD placement program...it would seem to me that the centroid location
> makes
> the most sense if there isn't any other reason why everybody uses pin-1.
> Maybe
> it's because that's the way everybody has been doing it over the
> years...kinda' dumb reason, but most of us are sheep anyway
> (GRIN)....B-a-a-a-
> a-a-a!
>
>                                                             -Steve
> Gregory-
>
> ################################################################
> TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
> ################################################################
> To subscribe/unsubscribe, send a message to [log in to unmask] with
> following text in the body:
> To subscribe:   SUBSCRIBE TechNet <your full name>
> To unsubscribe:   SIGNOFF TechNet
> ################################################################
> Please visit IPC web site (http://jefry.ipc.org/forum.htm) for additional
> information.
> For the technical support contact Dmitriy Sklyar at [log in to unmask] or
> 847-509-9700 ext.311
> ################################################################
>

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC web site (http://jefry.ipc.org/forum.htm) for additional information.
For the technical support contact Dmitriy Sklyar at [log in to unmask] or 847-509-9700 ext.311
################################################################


ATOM RSS1 RSS2