Valerie Webber
03/13/98 10:29 AM
Ok, bear with me as I am new to this e-mail forum thing.  This is my first
attempt at posting.

I would like information on the effects plating has on the current
distribution throughout my conductor.  For example, say I have two 40 um
traces with 40 um space between edges sitting on a dielectric.  I'm using a
copper alloy of only 40% IACS.  Now I throw 3 um of gold plating (78% IACS)
on the 3 exposed sides of my traces.

What is the distribution of current through this multi-layer conductor?
How does this distribution change with increasing frequency?
Is there a non-conductive barrier between the copper and the plating?
Trace pitch has stayed the same, but edge-to-edge spacing and trace
cross-section have changed.  Do I use the plated configuration in my RLC
calculations?
Is there modeling software suited for this?  I have a 2-d FEA package
(Ansoft), but it does not seem to handle 2 conductors sharing a boundary.
Maybe it does, but I'm doing something wrong?

I would appreciate being pointed in the direction of any literature,
experts, etc. that have investigated this issue.

Valerie Webber

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC web site (http://jefry.ipc.org/forum.htm) for additional information.
For the technical support contact Dmitriy Sklyar at [log in to unmask] or 847-509-9700 ext.311
################################################################


ATOM RSS1 RSS2