> There is a question I have had for several years;
> I though I understood the answer but now recognize
> that I don't. Perhaps some of our resident "Designer
> Council" experts or some IPC gurus can help.
>
> The problem involves the formulas for intrinsic
> capacitance of a trace, as published in IPC 317 and
> 317A. For stripline, the  formula for Co is:
> Co=1.41Er/Ln[3.81H/(.8W+T)]  (5.37 in 317A)
> for Asymetric stripline, the formula is:
> Co=2.82Er/Ln[2(H-T)/(.268W+.335T)]  (5.38b in 317A)
>
> This later formula can be manipulated to
> Co=2.82Er/[Ln[6(H-T)/(.8W+T)]
> which can be compared with Eq. 5.37
>
> Now assume a stripline case with
> H = 10  (mils)
> T = 1 oz
> W = 8
> Er = 4.3
>
> Co is calculated as 3.8 pf/in
>
> Now, simply move the lower plane very far away and use the
> asymetric stripline formula. You get 6.42 pf/in, roughly
> twice as much. But since you have only moved one plate
> AWAY from the trace, intuitively you'd think the capacitance
> would go DOWN by a factor of two, not up.
>
> Is there something wrong with my thinking, or with the
> formulas?????
>
> Thanks for the help.
>
> Doug Brooks
> .
> ****************************************************
> Doug Brooks, President              [log in to unmask]
> UltraCAD Design, Inc.           http://www.ultracad.com
>

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC web site (http://jefry.ipc.org/forum.htm) for additional information.
For the technical support contact Dmitriy Sklyar at [log in to unmask] or 847-509-9700 ext.311
################################################################


ATOM RSS1 RSS2