In a message dated 98-03-25 13:05:44 EST, [log in to unmask] writes:

<<
 Dave,

 The temperatures were actually lower than 183.  They ranged any where
 from 120 to 165.  The three solder pastes that passed the test melted at
 183 +/- 5.

 Kathy Palumbo >>

Kathy,

      Ranged from 120 to 165? WOW!! That's quite a difference! Hmmmmmm...I
wonder if something like that could be related to a thread that was going a
day or so ago about secondary reflow during wave soldering? It sure sounds
like it could...

                                                                      Interest
ing...

                                                                     -Steve
Gregory-

################################################################