Irwin, William D wrote:
>
> I have an Alpha Metals Ionograph model 500M that I have inherited from
> an engineer that is no longer with the company. Along with this piece
> of equipment I have only inherited internal procedures that look like
> they have been copied from the manual, but no manual.
>
> We have to calibrate or verify the solution by taking a specific gravity
> and running the test procedure. in this you use the reading you have
> taken above and add a know amount of contaminate to the unit. I am then
> looking for a reading of 37.5 (+/- something I'm assuming) for a pass.
> the problem I am having is that I am reading in the 420's to 460's and
> no one here has ever seen this unit fail. we also do not cover the fail
> contingency in our procedures. I have been leaving messages with Alpha
> Metals for 2 days with no reply.
>
> Help!!!!!!!!!!!!!!!!!!!! Has anyone encountered this and if so could you
> give me some guidance.
> Call me tomorrow, 201-434-6778 x 2222
Karen Tellefsen
Alpha Metals
> Bill Irwin
> [log in to unmask]
> Bill Irwin
> Berg Electronics
> (717) 764-7309
>
> ################################################################
> TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
> ################################################################
> To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
> To subscribe: SUBSCRIBE TechNet <your full name>
> To unsubscribe: SIGNOFF TechNet
> ################################################################
> Please visit IPC web site (http://jefry.ipc.org/forum.htm) for additional information.
> For the technical support contact Dmitriy Sklyar at [log in to unmask] or 847-509-9700 ext.311
> ################################################################
################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe: SUBSCRIBE TechNet <your full name>
To unsubscribe: SIGNOFF TechNet
################################################################
Please visit IPC web site (http://jefry.ipc.org/forum.htm) for additional information.
For the technical support contact Dmitriy Sklyar at [log in to unmask] or 847-509-9700 ext.311
################################################################
|
|
|