On 13 Jan 98, [log in to unmask] wrote:


>      Hi
>      What is the minimum distance recommended between TH leads and
>      the edge of the drilled hole insuring good solder filling
>      during wave soldering.  Which IPC standard number defined this
>      distance? Thanks in advance. Tamir
>

The appropriate IPC specification is IPC-D-275,  which lists numerous
design guidelines.  Specifically, see paragraph 5.4.8 and Table 5-15.

##############################################################