     I would like to understand the current capability of pcb manufacturing with
     respect to thermal relief. The 3 actions would be:

     1. PB mfg places thermal relief patterns at "true" locations in the
     aperture file.

     2. thermal relief are created at PB mfg based on text notes in aperture
     file. Text notes are complicated and must be associated with the correct
     "hole" in the case of multiple thermal relief.

     3. Area fill thermal ties will default to narrowest trace unless a text
     note in the aperture file is acted upon by PB mfg.

     Is this true?
     How do you control multiple thermal patterns?
     Is the thermal pattern still required?
     Are there any rules for current vs no thermal relief? ..like hole size,
     copper weight, etc.


     Steve

##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TECHNET <your full name>
To unsubscribe:   SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional information.
For the technical support contact Dmitriy Sklyar at [log in to unmask] or 847-509-9700 ext.311
##############################################################