Even water solvent at 140F can remove close to 15-20% of the Entek Plus
coating. The other more aggressive solvents remove significantly more.
Call Enthone-OMI to get a manual on Entek Plus which lists the percentage
of removal by each solvent. You may find sone information on its web site:
http://www.enthone-omi.com.

I qualified this process at my former employer. we used the in-line
aqueous cleaner to clean misprints.



Yuan Li
Research Associate
CAMPmode (Center For Advanced Manufacturing and Packaging of Microwave,
Optical and Digital Electronics)
University of Colorado at Boulder

##############################################################