TECHNET Archives

November 1997

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Robert Welch <[log in to unmask]>
Reply To:
TechNet Mail Forum.
Date:
Tue, 25 Nov 1997 13:30:16 +0000
Content-Type:
text/plain
Parts/Attachments:
text/plain (26 lines)
Annie,

Since you said oxidized, I'm afraid the condition you describr is due
to high lead content in the gold bath.  Almost all automatic Ni/Au
machines drag in a  small amount of lead into the gold bath,
regardless of how well everything is run.  Because of this the
gold bath itself must eventually be either treated for lead or
replaced.  I'm realy not sure if there is a functional impact.
Robert E. Welch
Process Specialist
Email: [log in to unmask]
Modem: 804-239-9120
Fax:   804-237-3048

##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TECHNET <your full name>
To unsubscribe:   SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional information.
For the technical support contact Dmitriy Sklyar at [log in to unmask] or 847-509-9700 ext.311
##############################################################


ATOM RSS1 RSS2