TECHNET Archives

November 1997

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Engineering / Design Dept." <[log in to unmask]>
Reply To:
Date:
Mon, 17 Nov 1997 11:28:20 -0800
Content-Type:
text/plain
Parts/Attachments:
text/plain (42 lines)
Ken Patel wrote:
>
> Wave Expert,
>
> How often one should take solder sample from the wave solder pot for content
> analysis (impurities)? Is there a guideline which assembly house should follow?
>
> re,
> ken patel
> ______________________________________________________
> Ken Patel                       Phone:  (408) 490-6804
> 575 Cottonwood Dr.              Fax:    (408) 490-6859
> Milpitas, CA 95035              Beeper: (888) 769-1808
>

It really depends on your usage. But you can figure this out easily.
Take a sample now and another in a month or so. Compare. If impurities
(delta) levels are too high then reduce cycle time. It may take you a
while to establish your cycle but it works.
--
******************************
     Mission Peak Services

   Engineering Department

        Visit us at:

  http://www.missionpeak.com
******************************

##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TECHNET <your full name>
To unsubscribe:   SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional information.
For the technical support contact Dmitriy Sklyar at [log in to unmask] or 847-509-9700 ext.311
##############################################################