I am considering to switch the plating used on our PCB's from HASL to
gold immersion. The reason I am considering making this change is to
improve the solder joint reliability of our 20mil components.
My company is a manufacture of RF products from 300MHz to 2.4GHz. When I
switch to gold immersion plating is there any electrical characteristics
I should be concerned about between gold immersion and HASL. Is there
any types of testing I should do to verify I did not change the
performance of my products.
Any information would be helpful.
Thank you for you time.
Dwayne Niewiemski
Director of Manufacturing Engineering
Microwave Data Systems
Rochester, New York
##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe: SUBSCRIBE TECHNET <your full name>
To unsubscribe: SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional information.
For the technical support contact Dmitriy Sklyar at [log in to unmask] or 847-509-9700 ext.311
##############################################################