TECHNET Archives

October 1997

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Condense Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Mime-Version:
1.0
Sender:
Subject:
From:
APeder01 <[log in to unmask]>
Date:
Tue, 21 Oct 1997 16:15:50 -0400
Content-Transfer-Encoding:
7bit
Content-Type:
text/plain; charset=US-ASCII
Reply-To:
"TechNet Mail Forum." <[log in to unmask]>, APeder01 <[log in to unmask]>
Parts/Attachments:
text/plain (29 lines)
     I'm a bit confused (not unusual) by two paragraphs in IPC-6012
     regarding lifted lands.

     3.3.4  Lifted Lands.  The finised board SHALL not exhibit any lifted
     lands.

     3.6.2.9  Lifted Lands.  Lifted lands are allowed after thermal stress
     provided that the visual criteria of section 3.3.4 are met.

     So, is this telling me that lifted lands are okay as long as I can't
     see them?  (If I can't see them, how would I know they were lifted?)
     Therefore, if there is visual evidence of a lift is it rejectable?
     Was the intent to allow or dis-allow lifted lands after thermal
     stress?

     Thank you for any clarification.

##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TECHNET <your full name>
To unsubscribe:   SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional information.
For the technical support contact Dmitriy Sklyar at [log in to unmask] or 847-509-9700 ext.311
##############################################################


ATOM RSS1 RSS2