Jim,  Are you temp cycling the coax after bending but before installing
connector(s) to stress relieve the PTFE dielectric?  That has given us
problems in the past, especially with short cable lengths.  Sheila Smith,
Tracor Aerospace


At 02:20 PM 9/26/97 -0400, you wrote:
>I'm trying to assemble semi-rigid coax cables made with MIL-C-17 RG402 .141"
>dia. cable and MIL M39012/79 P/N 3002 connectors.  The cables are being tested
>over a frequency range of 8 to 18 gigahertz, and the spec requirement is 1:1.2
>VSWR.  So far, we are getting approximately a 50% yield.  While bad cables are
>out of spec at room temperature, we did notice that if we have a marginal
>cable, it goes out of spec (many times to an RF open) when heat is applied (hot
>air gun no more than 150 degrees F).  Good cables hardly change at all.
>
>Are we pushing the limit with our tight VSWR requirements?  Should this be
>achievable?  If so, does anything come to mind as to what we might be doing
>wrong?
>
>Thanks in advance for your quick responses,
>
>Jim Marsico
>(516) 595-5879
>
>##############################################################
>TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
>##############################################################
>To subscribe/unsubscribe, send a message to [log in to unmask] with following
text in the body:
>To subscribe:   SUBSCRIBE TECHNET <your full name>
>To unsubscribe:   SIGNOFF TECHNET
>##############################################################
>Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
additional information.
>For the technical support contact Dmitriy Sklyar at [log in to unmask] or
847-509-9700 ext.311
>##############################################################
>

##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TECHNET <your full name>
To unsubscribe:   SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional information.
For the technical support contact Dmitriy Sklyar at [log in to unmask] or 847-509-9700 ext.311
##############################################################


ATOM RSS1 RSS2