TECHNET Archives

September 1997

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Eltek Ltd. - Process Engineering" <[log in to unmask]>
Reply To:
TechNet Mail Forum.
Date:
Thu, 11 Sep 1997 06:46:48 +0300
Content-Type:
text/plain
Parts/Attachments:
text/plain (32 lines)
Just Check , if Your new anion column is in regenerated form ( Anion column
might be Cl- form ) .
At 19:14 09/09/97 -0400, you wrote:
>I am currently having trouble with our DI system.  I have changed the carbon
>and replaced the resin in the anion column.  I also regenerated the cation
>column.  The trouble I have is that the microsiemens (microhms) reading will
>stay below 20 for only a few minutes and then it shoots off the meter.  Any
>comments or suggestions would be greatly appreciated.
>
>Thank you,
>
>Mark Wilkins
>
>
Edward Szpruch
Eltek Ltd - Israel
Tel  972 3 9395050
Fax 972 3 9309581
E-mail :  [log in to unmask]

##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TECHNET <your full name>
To unsubscribe:   SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional information.