I would add some to this suggestion... we use the double stick tape
also primarily because it enables us to eliminate the component skew
due to pushing the component onto the solder paste... however, also
realize that many placement machines make placement adjustments
depending on the lead verification algorithm if you are dealing with a
gull wing leaded device for example... also note that it is highly
likely that leads could be independently skewed 1 or 2 mils... another
issue is the tolerance on the nominal dimension of the component as
well as the error associated with the centroid of the component on the
board at the programming level.... I would consider all of these
'errors' when evaluating results... since we may be dealing with
fractions of a mil, the density of your test board may be an issue in
regards to the etching of the traces and their symmetry in respect to
the top of the pad geometry....
marcelo