John Urry @ SLG wrote:-
>I am looking for help on determining recommended dimensions for thermal   
>vias and thermal via legs (spokes).  I understand there is a trade-off   
>between making the vias large enough with small enough legs to allow the   
>board to be soldered without the use of a blast furnace versus making the   
>vias smaller with larger legs to allow for the required current capacity   
>of the connection.  Any suggestions would be most appreciated.

My advice would be to keep the cross-sectional area as large as possible
by using a two spoke thermal to the ground plane which you can design to
be as wide as you need. This would give you a wider trace than using
four spokes and avoid the possibility of break out toward a single
connection. If you tear drop the connections to the pad, it will
increase cross-sectional area of contact to the hole without increasing
the heat sink.

Someone else asked why put thermals on non-soldered vias? If the finish
is HASL then the holes will clear better if they are not connected
directly to a ground plane. It is no problem to add thermals and they
also help to determine good drilling registration over the whole panel.
Besides that, if a hole goes straight into a ground plane these days, I
always query the design in case there has been a data error.

Regards
-- 
Paul Gould
Teknacron Circuits Ltd
[log in to unmask]
Isle of Wight,UK

***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To subscribe/unsubscribe send a message <to: [log in to unmask]>   *
* with <subject: subscribe/unsubscribe> and no text in the body.          *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact   *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask]      *
***************************************************************************


ATOM RSS1 RSS2