jim -

there is a difference between low copper adhesion - UNDERPLATE - and poor
copper adhesion. Check exposing to meet parameters - check strength of
developing solution - Check pressure spray on developer - Check actual
nozzles - Check breakpoint on developer - Check cleaner - Check condition of
copper bath - without definite info as to what is occurring - hard to come up
with a pinpointed answer. Hope this helps.

Regards

Richard Fudalewski