TECHNET Archives

July 1997

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Condense Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Received:
by ipc.org (Smail3.1.28.1 #2) id m0wtwlu-000Bk5C; Thu, 31 Jul 97 10:04 CDT
Content-Type:
TEXT/PLAIN; charset=US-ASCII
Old-Return-Path:
<buetmi>
Date:
Thu, 31 Jul 1997 10:04:05 -0500 (CDT)
Precedence:
list
Resent-From:
Resent-Sender:
TechNet-request [log in to unmask]
MIME-Version:
1.0
X-Mailing-List:
<[log in to unmask]> archive/latest/14440
>From willli Thu Jul 31 10:
04:31 1997
TO:
Return-Path:
<TechNet-request>
X-Loop:
Resent-Message-ID:
<"D6hSe3.0.VMK.fbAup"@ipc>
Subject:
From:
Mike Buetow <[log in to unmask]>
From [log in to unmask] Thu Jul 31 12:
55:42 1997
In-Reply-To:
cc:
Message-ID:
<Pine.3.89.9707310945.A59167-0100000@ipc>
Parts/Attachments:
TEXT/PLAIN (45 lines)
IPC-SD-320 was canceled March 1992. It was superseded by IPC-RB-276, 
which was then superseded (in October 1996) by IPC-6012, the rigid board 
qualification specification.

I'm assuming IPC-A-6000 refers to the "0" revision of the standard; in 
other words, the original publication. If so, this was canceled in Sept. 
1979, and has been superseded several times. The current edition is 
IPC-A-600E, published in AUgust 1995. This is a pictorial representation 
of the requirements set forth in IPC-RB-276/IPC-6012.

Mike Buetow
IPC
2215 Sanders Road
Northbrook, IL 60062
P: 847-509-9700, ext. 335
F: 847-509-9798
[log in to unmask]


On Thu, 31 Jul 1997 [log in to unmask] wrote:

> From:  Stephen Ayotte
>        EM Quality Engineering
>        Bldg. 14-3 Col F5 5-1537
> Subject: Fabrication Specs
> 
> Any information on the following specs would be appreciated:
> 
> IPC-SD-320
> IPC-A-6000
> 
> they are not in my IPC manuals and do not know what they are
> about.

***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To subscribe/unsubscribe send a message <to: [log in to unmask]>   *
* with <subject: subscribe/unsubscribe> and no text in the body.          *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact   *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask]      *
***************************************************************************


ATOM RSS1 RSS2