Hi Jeff,
You are correct to worry about this. Non-symmetrical layups can be assemble,
but require special handling, in particular more extensive, and perhaps
depending on the severity of the non-symmetry unequal, pre-heating. The only
way to find out is to build some prototypes and assemble them fully loaded.
Make sure the prototype is build with the same material as would be the
product.
Werner Engelmaier
Engelmaier Associates, Inc.
Electronic Packaging, Interconnection and Reliability Consulting
23 Gunther Street
Mendham, NJ 07945 USA
Phone & Fax: 973-543-2747
E-mail: [log in to unmask]
***************************************************************************