[log in to unmask] wrote:
>
> I have just recieved results to a TMA test for z-axis expansion and
> a TGA for weight loss on a 260 Tg polyimide material. I was told that the
> results are bad, however, I have nothing to bench mark the results against.
> Does anybody know what a typical good result for these tests are for this
> type of material and or any other materials. Any comments would be greatly
> appreciated.
We have one high reliability electronics customer that specifies a
minimum Tg 250 degrees C on polyimides. Generally, the higher the Tg
the lower the coefficeint of thermal expansion in the temperature region
that boards see during processing. This in turn means less stress in
the plated through holes. The Tg of polyimides may be lowered by
moisture content. You may want to dry the boards if they have had a
chance to pick up moisture.
As far as TGA goes, this is not typically performed on boards or cured
board materials. But, it will give an indication of resin content and
may provide you with some useful information. If the resin content is
significantly out of tolerance it will impact the board thickness.
You may want to check the overall thickness as well as the
dielectric thickness on each layer.
--
John Moylan
President
Delsen Testing Laboratories, Inc.
1024 Grand Central Ave.
Glendale, CA 91201
Phone: 818 247 4106
FAX 818 247 4537
email: [log in to unmask]
URL: http://www.primenet.com/~delsen/
Delsen Testing Laboratories, Inc. is an independent testing
laboratory primarily engaged testing advanced materials.
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To subscribe/unsubscribe send a message <to: [log in to unmask]> *
* with <subject: subscribe/unsubscribe> and no text in the body. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
|
|
|