Rich Everman (tel) 812-634-4401) (fax) 812-634-4700
Kimball Electronics Group - - Jasper, IN 47549-1003
PWB Component Engineer [log in to unmask] |
Message-Id: |
|
Parts/Attachments: |
|
|
Tony,
Excellent report! I am curious what your surface mount pad geometries
for wave solder on the 0805 and the case A Tantalum Caps were?
Kimball Electronics Group Surface Mount Pad Geometries for
0805
WAVE SOLDER ATTACHMENT METHOD
pad height: .060 pad width: .040
pad spacing from center to center: .090
CASE A TANTALUM CAPACITORS
WAVE SOLDER ATTACHMENT METHOD
pad height: .065 pad width: .065
pad spacing from center to center: .104
=-=-=-=-=-=-
Tony wrote...
From: "D. A. (Tony) Stewart" <[log in to unmask]>
To: [log in to unmask]
<b> Subject: Solution: No Solder on Size "A" Tant Caps after WAVE also
SOT-23's </b>
After building 4000 PCA's for a customer, which has 14 Case Size "A"
Tant. Caps out of approx 400 parts on the wave side, it was found that
PCA's averaged 14 "No Solders"/PCA after wave. (50% joints of 28 in
random positions) Almost all the defects were on these Case Size "A"
component types. Case size "D" Tant Caps and 805 ceramic parts were
defect free. What is unique about Tant SM caps is that the leads only
travel half-way up the body , unlike ceramic chips which terminal
surround the ends. The Case size "D" had larger lands. Occasionally
defects for excess solder were found as a result of trying to increase
the solder flow to these difficult parts. (eg slower feed rate, higher
chip wave etc. The SOLTEC wave soldering machine uses a foam fluxer (No
Clean flux) with good foam height and bubble size. An experiment to hand
spray flux reduced the qty of defects to 4/PCA, but did not make the
process defect-free. (Yes we know foamers are not the best kind)
To make the process Defect-Free and specifically free of "No Solder"
joints, we measured a sample of exposed solder lands and checked a
variety OK and "bad (NS)" joints. The result was there were 0 joints
with 0.060 (1.5mm) exposed lands that failed. Since it was too late to
change the pad design for this production run, we considered 1) do
nothing except continued 100% inspection, 2) hand-solder both ends, 3)
offset the part, leaving only one joint requiring hand solder. This was
considered better than leaving inspection to chance. To offset the parts
0.5mm or 20 mil on the Fuji placement offset, would provide 100%
probability of lead soldering . The pad size allows contact with the
0.8mm (32mil) terminal length with the offset and then manual soldering
of only 1 joint is required. This is expected to reduce the process
variable of Case Size lead solderability to zero and make this part of
the process defect-free.
Other Opportunities
====================
Interesting enough we theorize this solution will fix SOT-23 "No
solder" problems. I've read the history of people who have had problems
on this part. If you can, increase the land size to accomodate your
wave soldering process or in the Size "A" Tant Case here .060" or
1.5mm. Don't put too much faith into IPC-782 design requirements. They
are only guidelines. Determine your own optimum LAND Designs and
provide input to your customer's design.
EXPERIMENTAL DATA
Exposed Lands Inspected Joints to IPC class2
[thou] [mm] % bad % OK
====== ===== ===== =====
0.000 0.00 100% 0%
0.010 0.40 100% 0%
0.020 0.80 50% 50%
0.030 1.20 50% 50% worst case
0.040 1.60 33% 67% this is IPC782 guideline size
0.050 2.00 43% 57%
0.060 2.40 0% 100% defect free on several batches inspected
0.070 2.80 0% 100%
0.018 0.73 Kemet MIN. Land Length Case size "A" Tant Caps
0.031 1.23 Kemet NOM. Land Length
Note that KEMET does not have a MAX!!
0.040" 1 IPC782A MAX Land Length (calculated)
Haven't checked Rev B yet
0.060 1.5 mm C-MAC MIN Land Length for No clean flux with foam
fluxer
on SOLTEC wave
RSVP by e-mail
regards,
Tony
Eng Manager Web: http://cmac.ca
***************************************************************************
//-
Rich Everman (tel) 812-634-4401 (fax) 812-634-4700
Kimball Electronics Group - - http://www.kimball.com
PWB Component Engineer - - reverma@kimball..com
//-
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To subscribe/unsubscribe send a message <to: [log in to unmask]> *
* with <subject: subscribe/unsubscribe> and no text in the body. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
|
|
|