TECHNET Archives

June 1997

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Condense Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Received:
by ipc.org (Smail3.1.28.1 #2) id m0wbqBF-000BjMC; Wed, 11 Jun 97 11:23 CDT
>From willli Wed Jun 11 11:
24:15 1997
References:
Date:
Wed, 11 Jun 1997 12:25:39 -0400
Precedence:
list
Reply-To:
Resent-Sender:
TechNet-request [log in to unmask]
MIME-Version:
1.0
Status:
O
X-Mailing-List:
<[log in to unmask]> archive/latest/13311
From [log in to unmask] Tue Jun 17 10:
47:08 1997
TO:
X-Status:
Return-Path:
<TechNet-request>
X-Loop:
Resent-From:
Content-Type:
text/plain; charset=us-ascii
Content-Transfer-Encoding:
7bit
Resent-Message-ID:
<"h0ePe1.0.QHD.c3jdp"@ipc>
Subject:
From:
[log in to unmask] (Doug McKean)
Old-Return-Path:
X-Mailer:
Mozilla 3.01 (Win95; I)
Organization:
Paragon Networks Int'l
Message-ID:
Parts/Attachments:
text/plain (36 lines)
Thought I had sent this out once before. 
Sorry if this is a repeat ... 

We have a product requires thermal testing -

 50 degrees C
 Power ON
 full functional setup
 total high temp time = 72 hours

PRIOR to electronic bench testing. We do this to weed out
an infant mortality with board assembly, bad chips, etc...

Now, if the bench test discovers or as indicated by front
panel leds some failure and some rather large ICs
need to be replaced, does the entire assembly go back
through full cycle temp testing?

This could have a major impact on stock and ship quantities.
Plus only so many products can go in the chamber. Any
retest knocks out *new* products coming through in the
regular flow.

Comments, thoughts, even speculations welcome.

***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To subscribe/unsubscribe send a message <to: [log in to unmask]>   *
* with <subject: subscribe/unsubscribe> and no text in the body.          *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact   *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask]      *
***************************************************************************


ATOM RSS1 RSS2