Ive been reviewing a CCA that will be using commercial components at
elevated temperatures. I've typically found that commercial ICs are
rated from 0 oC to 70 oC ambient temperature.
Does anyone have information on what "ambient" is? i.e. natural or forced
convection
If forced convection, what air velocity, volume flowrate or mass
flowrate?
Is there a standard test used for rating components at 70 oC ambient and
if so, could someone direct me to where I can find information on that
test.
Thanks for the help.
Hans Ohman
DY4 Systems Inc.
[log in to unmask]
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To subscribe/unsubscribe send a message <to: [log in to unmask]> *
* with <subject: subscribe/unsubscribe> and no text in the body. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************