There has been some discussion on panel sizing recently.  I didn't know it
was a issue still.  Anyway, I wrote a Lotus 123 progam in 87 (had an 11/87
file date till today) that calculates the optimum panel size for panel based
on some standard sheet sizes and does both military and commercial.  It was
a pretty complicated program, actually generated a quotation.  I wrote this
for a customer who is long out of business and out of the business so I'll
pass it out if someone wants it.  The prices are a bit dated, probably too
high =8-0, but you can take the protection off and rework whatever you want.

Send me a direct e-mail at [log in to unmask] and I'll send it to you.  This
is copywrited and I don't expect to see a version advertised for sale in
Circuitree or PC Fab!  It's not that great...

Here are a couple of pages from it.


>>>>>>>>>This is the help section (not much but this was 10 years ago),<<<<<

THIS IS THE HELP AREA.  TO RETURN HERE FOR INSTRUCTIONS FROM ANYWERE ELSE IN
THE PROGRAM, PRESS THE {ALT} AND THE {M} KEYS AT THE SAME TIME.  {ALT M}  THEN
ENTER {HELP} AT THE COMMAND PROMT (TOP OF SCREEN) (DO NOT TYPE THE {} BRACKETS)

TO MOVE THE CURSOR AROUND, USE THE ARROW KEYS TO MOVE THE DIRECTION YOU WANT
TO GO.  THE ARROW KEY ALSO ACTS AS AN ENTER (OR CARRIAGE RETURN) TO ENTER DATA.


TO BEGIN THE PROGRAM PRESS {ALT M} THEN TYPE {BEGIN} WHICH WILL PLACE THE
CURSOR AT THE BEGINNING OF THE ENTRY DATA FILE.  MOST OF THE WRITING YOU SEE ON
THE SCREEN IS PROTECTED AND IS NOT EASILY CHANGED.  ALL DATA IS ENTERED IN
COLUMN
B, EXCEPT WHERE PROTECTED.  PROTECTED ROWS HAVE THE WORD "AUTOMATIC IN
COLUMN "C"
MEANING THAT THIS IS AN AUTOMATIC CALCULATION.

ERROR MESSAGES AND SEE ENGINEERING MESSAGES ARE DISPLAYED IF YOU MAKE AN IN-
CORRECT ENTRY.  THE MOST COMMON ERRORS WILL RESULT FROM MIS-ENTERING
INFORMATION.
PLEASE CHECK YOUR ENTRIES IF YOU GET AN ERROR MESSAGE.

THE PROGRAM SELECTES THE OPTIMUM PANEL SIZE FROM THOSE AVALILABLE.  THE PROGRAM
SELECTS ON A BASIS OF SQUARE FOOTAGE OF MATERIAL WASTED FOR THE ENTIRE ORDER.
SOMETIMES IT MAY NOT BE DESIRABLE TO RUN LARGE PANELS.  WHEN {ALT S} IS PRESSED,
YOU WILL SEE A TABLE TO THE RIGHT AND THE CURSOR UNDER THE OPTIMUM PANEL SIZE.
THE TABLE LISTS THE NUMBER OF BOARDS/PANEL AND THE AMOUNT OF SQUARE FOOTAGE
WASTED
FOR EACH PANEL SIZE.  TO SELECT ANOTHER PANEL SIZE, PLACE THE CURSOR UNDER THE
OPTIMUM  PANEL SIZE AND ENTER THE NUMBER TO  THE LEFT OF THE PANEL SIZE YOU WISH
TO PRICE.  TO SEE THE NEW PRICEING, PRESS {ALT M}{DETAIL}

{DETAIL} VIEWS THE FINAL FORM WHICH  IS PRINTED OUT WHEN YOU  SELECT {PRINT}.
NOTHING CAN BE CHANGED ON THIS FORM EXCEPT BY REENTERING IN THE DATA ENTRY FILE
{BEGIN}


	WELCOME TO THE REMCO ENGINEERING PRICING PROGRAM	
		
		
		
HELP		HELP (THIS FILE)
		
BEGIN		BEGIN (MOVES TO DATA ENTRY FILE)
		
SIZE		SIZE (SELECTS A DIFFERENT SIZE PANEL FOR PRICING)
		
DETAIL		DETAIL (SUMMARY OF ORDER AND PRICING)
		
PRINT		PRINT (PRINTS DETAILED SUMMARY OF ORDER AND PRICING)
		
ERROR		SEE ERROR LIST
		
PRICE		VIEW PRICING
		
SAVE		SAVE FILE BY  QUOTE NUMBER
		
ENG		GO TO NRE AND NRT ENG CHARGES
		
REVIEW		REVIEW A QUOTE FILE



>>>>>>>>>This is the fill in form.<<<<<<<<<<<<<<<<
	
REMCO ENGINEERING PRICING PROGRAM	
	
PLEASE ENTER THE FOLLOWING INFORMATION IN THE SPACE PROVIDED.  PRESS (DOWN)
ARROW	
KEY AFTER ENTERING INFORMATION.  PRESS {alt M} {ERROR} FOR ERROR LIST	
	
TODAYS DATE: --------------------------	10-8-87
QUOTED BY:  ---------------------------	DAVE
QUOTE NUMBER  -------------------------	1
CUSTOMER NAME (COMPANY):  -------------	JOES PCB CO.
CONTACT:  -----------------------------	MARK O.
PHONE NUMBER:  ------------------------	0
PART NUMBER:  -------------------------	623917
REVISION NUMBER OR LETTER:  -----------	E
BOARD LENGTH (CONTACT SIDE)------------	8.00
BOARD WIDTH ---------------------------	4.50
QUANITY REQUIRED:  --------------------	100
BOARDS PER PANEL  ---------------------	6
NUMBER OF LAYERS:  --------------------	2
BORDER WIDTH IN INCHES-----------------	0.50
SPACING BETWEEN BOARDS ON PANEL  ------	0.25
TYPE OF MATERIAL(E,PI,FR):  -----------	1
COPPER CLAD:  (IN OUNCES)--------------	1
COPPER PLATE> 0.0015,SOLDER OVER 0.0006	2
PERIMETER IN INCHES  ------------------	25
FINAL THICKNESS REQUIRED: (0.XXX)------	0.062
PANEL SIZE:  (SQUARE INCHES)-----------	288
MIL OR COMM:  -------------------------	2
IS HOLE SIZE UNDER .030 OR OVER .257?	2
NUMBER OF HOLES:  (.030 MIN, .257 MAX)	286
SOLDER MASK, NUMBER OF SIDES:  --------	2
WET OR DRY(W OR D):  ---------------	1
BARE COPPER (1) OR TIN-LEAD (2):  --	2
LEGEND, NUMBER OF SIDES:  -------------	1
SOLDER LEVEL PANELS?  -----------------	2
REFLOW SOLDER PANELS?  ----------------	1
ETCHBACK ON DOUBLE SIDED?  ------------	2
GOLD CONTACT LENGTH:  -----------------	0
CHAMFER,BEVEL,KEY SLOTS, TOTAL/BOARD: -	0
MICROSECTION (Y OR N)  ----------------	2
ELECTRICAL TEST (Y OR N)  -------------	2
TRACES AND/OR SPACES LESS THAT 0.010? -	2
REPRESENTATIVE COMMISSION  (%) --------	0
DELIVERY TIME IN WEEKS:  --------------	6
QUICK DELIVERY (IN DAYS)  -------------	0
OVERSIZE PANEL? (>18x24) --------------	2
SPECIAL BOARD CHARGES -----------------	0.00
==========================================================================	
NRT & NRE	
FILM CHARGE?  --------------------------	1
DRILL TAPE?  ---------------------------	1
ROUTER TAPE?  --------------------------	1
ELECTRICAL TEST SETUP?  ----------------	2
HARDWARE, TERMINALS, STANDOFFS, EYELETS	0
CONTACT TEARS, INSTALLED  --------------	0
HARDWARE INSERTING TOOL?  (AT $75.00)---	2
HEAT SINK QUANITY ----------------------	0
HEAT SINK MATERIAL(SQ.IN.EACH) COPPER---	0.00
NICKEL PLATING? -------------------	2
HEAT SINK MATERIAL(SQ.IN.EACH) ALUMINUM-	0.00
ANODIZING?  -----------------------	2
BONDING CHARGE ($15.OO EACH)  ----------	2
SPECIAL BONDING CHARGE - SEE ENGINEERING	0
HEAT SINK TOOLING CHARGE----------------	0
EXTRA TOOLING CHARGE  ------------------	0.00
HEAT SINK ONLY?-------------------------	2
============================================================================	

Next - Calculating board size, note you can force a size (got a lot of 11 x
13 left over?).

============================================================================	
		COMMERC.	SELECT BEST MILITARY SIZE			MIL1-W	MIL2-L
			1 OR 2--->	1	<--HERE		
OPTIMUM SIZE						L X W	L X W
L X W		18 X 16	18 X 18			18 X 18	24 X 12
ENTER ALTERNATE ->		0.00	>>>>>>>>>>		ENTER ALT>	0.00	0.00
							
MINIMUM WASTE-SQ.FT		7.14	11.39			11.39	23.90
PER ORDER							
							
PANELS/ORDER		17.00	17.00			17.00	25.00
							
AREA		288.00	324.00			324.00	288.00
							
BOARDS PER PANEL		6.00	6.00			6.00	4.00
							
						======================================================================
================	

Remco Engineering (remco.com/home.htm)
Industrial Water and Wastewater Treatment Systems
San Luis Obispo, California  USA

***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To subscribe/unsubscribe send a message <to: [log in to unmask]>   *
* with <subject: subscribe/unsubscribe> and no text in the body.          *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact   *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask]      *
***************************************************************************


ATOM RSS1 RSS2