Subject: | |
From: | |
Reply To: | |
Date: | Mon, 07 Apr 1997 08:31:55 -0700 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
The following info in picked from UL Standards, specifically from:
UL DIRECTORY,
PLASTIC RECOGNIZED COMPONENT DIRECTORY
Polimeric Materials, Processes & Systems
Chapter Plastics-QMFZ2 (page 5)
----------------------------------------------------
Comparative Tracking Index (CTI) is expressed as that voltage which
causes
tracking after 50 drops of .1 percent ammonium cloride solution have
fallen
on the material. The results of testing the nominal 3 mm thickness are
considered representative of the material's performance in any
thickness.
CTI Range - Tracking Index Assigned PLC
(in volts)
600 and greater 0
400 through 599 1
250 through 399 2
175 through 249 3
100 through 174 4
Less than 100 5
-----------------------------------------------------
Major suppliers of FR4 material in US give an index of 2 to their
materials.
You might receive more information by contacting directly these
suppliers.
Julian
Bogdan Gaby wrote:
>
> Dear TechNetters
> Please could you give me some information about what the
> COMPARATIVE TRACKING INDEX is ?
> Where can I get a comparison between materials concerning this matter?
> What tests have been made?
> Please,don't let me down!
> As always thankful to all
> Gaby
>
> ***************************************************************************
> * TechNet mail list is provided as a service by IPC using SmartList v3.05 *
> ***************************************************************************
> * To subscribe/unsubscribe send a message <to: [log in to unmask]> *
> * with <subject: subscribe/unsubscribe> and no text in the body. *
> ***************************************************************************
> * If you are having a problem with the IPC TechNet forum please contact *
> * Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
> ***************************************************************************
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To subscribe/unsubscribe send a message <to: [log in to unmask]> *
* with <subject: subscribe/unsubscribe> and no text in the body. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
|
|
|