Received:
by ipc.org (Smail3.1.28.1 #2) id m0wKPqr-000Bj1C; Thu, 24 Apr 97 09:50 CDT
From [log in to unmask] Tue Apr 29 09:
41:26 1997
References:
Resent-Message-ID:
<"2Jp2q.0.OwK.mCtNp"@ipc>
Subject:
From:
Jan Merstrand <[log in to unmask]>
Cc:
X-Mailer:
Mozilla 4.0b3 [en] (WinNT; I)
Organization:
Ericsson Microwave Systems, Borås
Message-Id:
Parts/Attachments:
text/plain (44 lines)
[log in to unmask] wrote:

> Elizabeth:
>
> >From the limited data that you have provided, I would say that the
> problem
> here is that the flux has dried out prior to the wave or that the
> flux has
> not been applied at all in the areas that look bad.
>
> The solder pot temperature of 500?F is acceptable. The topside board
>
> temperature of 210? - 220?F also is within normal limits but, it is
> on the
> high side. I would suggest that your customer either turn up the
> conveyor
> speed or turn down the pre-heat to the extent that the topside
> temperature
> would be between 180? - 200?F. In addition, I would make sure the
> board is
> being adequately fluxed.

Bill,
>From my own experience i don't think that neither 210-220F or 180-200F
makes much difference in the bridging matter but the flux has a great
influence. I would check the mask and flux if they match and also if
there's any large amounts of oxides on the wave.

/Jan Merstrand



***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To subscribe/unsubscribe send a message <to: [log in to unmask]>   *
* with <subject: subscribe/unsubscribe> and no text in the body.          *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact   *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask]      *
***************************************************************************



ATOM RSS1 RSS2