TECHNET Archives

March 1997

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Bill Gaines B160 x2199 <[log in to unmask]>
Date:
Thu, 27 Mar 97 10:23:42 PST
Content-Type:
text/plain
Parts/Attachments:
text/plain (32 lines)

The current revision of this spec is NHB5300.4(3A-2)  (January 92)

We are using an aquious cleaner for all the boards we clean here, but we 
don't have much volume & hand solder most (I think actualy all) our boards.

We are working under the 3A-2 (and 3G-1,3H,3J...)

We use mostly watersoluble fluxes, except for hand solder & rework.

All boards are cleaned with the aquious cleaner.  I believe we check 
with an omegameter.  The initial work thru for NASA we tested the water
sepprately for contaminits.  We also wrote a suppliment (approved by GSFC)
to the 3A-2 to clarify certian aspects of the spec & define allowable conditions
(white residue after cleaning, lead overhang, ect ~9pages)  this was a long
process, but well worth it when it's time to submit material to the customer.

Bill Gaines
AeroJet

***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************