Mike,
You will find that in IPC A 600 E (Acceptability Guidelines) and in IPC RB 276 section 3.11 the mask requirements are clearly defined. With regard to mask coverage of reflowed parts, the requirements would be the same since the concern is not with potential exposed copper degradation but potential bridging of conductive surfaced during assembly.
Hope this helps,
Ed Cosper
Director Quality Assurance and Engineering
Graphic Electronics Inc.
Tulsa, OK
----------
From: Mike Masters[SMTP:[log in to unmask]]
Sent: Tuesday, March 25, 1997 6:56 AM
To: [log in to unmask]
Subject: Solder Mask Coverage and exposed SN/PB and Copper
I have a question that is two fold. It concerns Solder Mask coverage on PCBs.
IPC 610B addresses this issue some what but does leave a lot out. I am tasked
to set a standard for Mitsubishi Semiconductor for solder mask coverage on PCBs
and to determine when the manufacturer fails the criteria.
1. Question 1: What publications are available showing industry
standards for solder mask coverage over bare copper as well as over
SN/PB? I am aware of IPC 610B.
2. Question 2: Hoe much solder mask coverage is necessary for traces
that are already SN/PB coated? I do have a standard for exposed bare
copper. I am thinking especially for those traces that are adjacent to
each other with at best an 8 mil lines and spaces.
Any response would be helpful, Thanks
--
/\
_\/_
/_/\_\
Mike Masters
QA Materials Engineering Section
Office: (919) 479-3771
FAX: (919) 479-3328
Internet: [log in to unmask]
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To subscribe/unsubscribe send a message <to: [log in to unmask]> *
* with <subject: subscribe/unsubscribe> and no text in the body. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To subscribe/unsubscribe send a message <to: [log in to unmask]> *
* with <subject: subscribe/unsubscribe> and no text in the body. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
|
|
|