At 23:35 19/03/97 GMT+0500, you wrote:
>Hi there,
>
>Can any one out there tell me the test coupons that I should use during PCB
>fab. Are there any specs available??
>My e-mail id is [log in to unmask]
>
>Thanks in advance.
>
>regards.
>avi..
>

IPC-2141 & IPC-D-317 contain the relevant information.

Please contact me off line if you would like to discuss a specific issue.

Best regards

Andy Burkhardt <[log in to unmask]>
Tel: + 44 1481 53081
Fax: + 44 1481 52476
http://www.polar.co.uk
----------------------------------------------------------------------
World leaders in PCB faultfinding and controlled impedance measurement
----------------------------------------------------------------------

***************************************************************************