TECHNET Archives

March 1997

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Date:
Fri, 14 Mar 1997 11:23:19 -0500 (EST)
Content-Type:
text/plain
Parts/Attachments:
text/plain (26 lines)
Ed - The kinetics of the oxide reaction on fine lines can be compromised by a
galvanic cell set up between the copper and underlying foil treatment.  This
treatment, usually zinc, is exposed after etching.  It's only a fine line at
the copper epoxy interface but the galvanic cell is strong enough and results
in little or no oxide formation.  Ground planes and/or larger copper areas
have enough copper surface that the oxide reaction overcomes the galvanic
cell and the oxide forms properly.

There are several ways to overcome this "cell" problem.  Mostly, improved
surface preparation is the answer.

Roger Mouton
INSULECTRO

***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To subscribe/unsubscribe send a message <to: [log in to unmask]>   *
* with <subject: subscribe/unsubscribe> and no text in the body.          *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact   *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask]      *
***************************************************************************



ATOM RSS1 RSS2