further to early message, we have done a series of trials.
inspect panels after copper plating no dull copper
tin plate few panel, etch ,tin strip( from above panels) dull copper pads
tin plate few panels, tin strip ( from above panels) dull copper pads
pass panels after copper plating with photoresist on
through tin strip dull copper pads
so we concluded that tin stripper we use is the culprit
so we did trials with 3 different nitric acid based strippers and
one bifluride based stripper dull copper pads
so worked on ways to remove the dullness or passivation
microetch 5 micron run through electroless nickel line less nickel on
dull pADS
dip in alkaline cleaner of blackoxide ( to remove anti
tarnish of tin stripper do
dip in alkaline cleaner and brush pu mice clean do
(normally we brush before masking)
increase concentration of palladium in activator ( 3times) do
increase immersion time in activator to 10 minutes
with 3 timespalladium background plating but less nickel on dull pad
deburr boards after tin strip at normal deburring problem seems
pressure, then H2SO4 clean, brush to be less but
still exist.
to check whether intermetallic is the cause,
we did black oxide of boards after tin strip oxide takes place but observed
shade difference in dull pads
after H2SO4 STRIP
of b.o dull pads seen.
gosh, what is this dull pad ?
those who use acid tin and nitric acid based stripper see this dull pads after tin strip ?
the dull pads are seen in boards going through HASL also but do not create any problem there.
is it a elctroless nickel chemistry problem
--------------------------------------------------------------------------------
original message
we find less or no nickel plating in few pads after eletroless nickel - immersion gold process. this can be identified by inspecting the panels at an angle. on good pads , we get 4 to 5 micron nickle and 0.06micron and these bad ones as low as 0.4 micron nickel but we find gold thickness higher always above o.1 micron.
we found dullcopper pads after soldermasking and went back and found same dullpads after tin stripping.
we use acid tin as etch resist and nitric acid based stripper for tin stripping.
on a qfp ,a typical dull pad is as follows
- - bright pad
- - bright pad
- - dull pad after tin stripping
- - bright pad
- - bright pad
the dull pads occurr at random in a qfp.at times pads connected through a connector are dull.at times some portion of connecting track is also dull. since just one pad is dull and adjacent pads are bright indicate that it is unlikely to be copper plating problem.
we did hot air solder levelling of boards found after tin stripping with dull copper pads and found them to solder well.
has any onefound similar problem?
what is the likely cause ? intermetallics? if so how to identify presence of it and removal.
any help will be much aprreciated.
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************