Bill,
I have experienced the condition you are describing when we were
using similar process materials and equipment.
We found RANDOM granular solder joint occurred were there was large
thermal mass that resulted in very slow cooling of those joints. Solder
joints at heavy voltage or ground planes, buss bars, and components that
had large leads, would often result in this condition.
We were able to reduce this some by providing additional cooling at the
exit of the wave to help cool the assembly quicker and by dropping our
processing temperatures a little.
Dan Botts
Hughes Training Inc.
------------------------ INTERNET MAIL ------------------------
From: "BROMLEY, Bill" <[log in to unmask]>
Subject: ASSY:Grainy wave solder joints
Date: Tue, 18 Mar 97 16:05 EST
---------------------------------------------------------------------------
We are currently experiencing random grainular solder joints on double
sided rigid PWB assemblies after wave solder. Our wave solder machine is an
Electrovert Econopak 229, and we are using Alpha 615-25 (RMA-type) flux
with Sn6337 solder per QQ-S-571. The PWB is GHN type per Mil-P-13949/5 with
"C" type copper, and solder coated, with a dry film soldermask. We have
made many process adjustments, including speed, top-side board temperature,
wave bath temperature, etc. We have very recently verified that solder
purity is within specifications. The graininess we are seeing in the solder
joint (including the fillet area) is randomly distributed, and in some
cases located one pad from a perfect solder joint. There is no consistent
pattern from board to board. Can anyone offer some advice?
Bill Bromley/Mike Polifrone
Lucas Aerospace PSA
777 Lena Dr.
Aurora OH 44202 USA
voice: 216-995-1000 ex 7036
email: [log in to unmask]
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To subscribe/unsubscribe send a message <to: [log in to unmask]> *
* with <subject: subscribe/unsubscribe> and no text in the body. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To subscribe/unsubscribe send a message <to: [log in to unmask]> *
* with <subject: subscribe/unsubscribe> and no text in the body. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To subscribe/unsubscribe send a message <to: [log in to unmask]> *
* with <subject: subscribe/unsubscribe> and no text in the body. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
|
|
|