TECHNET Archives

March 1997

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Condense Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Mime-Version:
1.0
Content-Type:
text/plain; charset="us-ascii"
From [log in to unmask] Fri Mar 21 11:
23:49 1997
Date:
Fri, 21 Mar 1997 14:47:54 GMT
Precedence:
list
Resent-From:
Resent-Sender:
TechNet-request [log in to unmask]
X-Status:
Status:
O
X-Mailing-List:
<[log in to unmask]> archive/latest/11266
X-Sender:
[log in to unmask] (Unverified)
TO:
Return-Path:
<TechNet-request>
X-Loop:
Received:
by ipc.org (Smail3.1.28.1 #2) id m0w85To-000BCYC; Fri, 21 Mar 97 08:39 CST
Resent-Message-ID:
<"UU_WY2.0.uEH.ZsfCp"@ipc>
Subject:
From:
Andy Burkhardt <[log in to unmask]>
Old-Return-Path:
Cc:
John Reardon <[log in to unmask]>, John Coviello <[log in to unmask]>
X-Mailer:
Windows Eudora Light Version 1.5.2
Message-Id:
Parts/Attachments:
text/plain (74 lines)
At 10:21 20/02/97 PST, you wrote:
> 
>I have seen a lot of information regarding striplines and microstrips,   
>but what about two traces routed as a pair without ground planes.  It is   
>quite common in a Printed Circuit Board that there is a need to route a   
>pair, like a tip and ring of a T1.  These should be a controlled   
>impedance to ensure minimize reflections,  these also need to be void of   
>ground or power planes to minimize noise and impedance to ground.  Does   
>there exist an equation to determine the impedance between two traces   
>without ground planes?  
>
>***************************************************************************
>* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
>***************************************************************************
>* To subscribe/unsubscribe send a message <to: [log in to unmask]>   *
>* with <subject: subscribe/unsubscribe> and no text in the body.          *
>***************************************************************************
>* If you are having a problem with the IPC TechNet forum please contact   *
>* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask]      *
>***************************************************************************

John,

Yes there are, but the maths is not simple.  The structure you are referring
to is a co-planar strip transmission line.  This may be constructed on a
single layer PCB or it is possible to add a ground plane.

The formula involves evaluation of Elliptic Integrals, but you may be able to
get an approximate correlation with the following simplified equation for a
parallel twin line (two wires side by side, wire radius = a, centre to centre
spacing distance = d, Dielectric constant of spacing medium = Er)

        Zo = (120/SQR(Er))*ln(d/a)

        where ln is natural log and d >> a

I would also suggest substituting Er' (Effective dielectric constant) for Er.
eg Er(AIR) = 1, Er(FR-4) = 4, so Er'(AIR&FR-4 combination) = 3 (approx)

A good indepth book on the subject is:
 
"Transmission Line Design Handbook", by Brian C. Wadell
 
1991 Artech House, Inc, ISBN 0-89006-436-9
 
         Artech House Publishers
         685 Canton Street               Tel: (617) 769-9750
         Norwood, MA 02062               Fax: (617) 769-6334
 
I hope this information helps.  Please email me if you require further
assistance.

Best regards

Andy Burkhardt <[log in to unmask]>
Tel: + 44 1481 53081
Fax: + 44 1481 52476
http://www.polar.co.uk
----------------------------------------------------------------------
World leaders in PCB faultfinding and controlled impedance measurement
----------------------------------------------------------------------

***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************