We perform the test routinely. Other approximately equivelent
methods (5% NaCl, 95 degrees F) include ASTM B 117 and MIL STD 202,
Method 101 and MIL STD 1344 for connectors. Note the test durations may
vary. MIL STD 883 and 750 use different conditions (1% NaCl
concentration) to test parts at the component level.
The salt spray or fog test is ususally performed on finished assemblies
that are exposed outdoors, on mated connectors or to evaluate metal
finishes. It is an accelerated corrosion test. We have performed the
test on assembled boards, but it is an uncommon request. Feel free to
call me if I can be of more help.
--
John Moylan
President
Delsen Testing Laboratories, Inc.
1024 Grand Central Ave.
Glendale, CA 91201
Phone: 818 247 4106
FAX 818 247 4537
email: [log in to unmask]
URL: http://www.primenet.com/~delsen/
Delsen Testing Laboratories, Inc. is an independent testing
laboratory primarily engaged testing advanced materials.
>
> Subject: Time: 9:18 AM
> OFFICE MEMO ASSY/TEST: Salt Fog Test Date: 2/5/97
>
> We have been asked to conduct a Salt Fog Test on some assembled, functional
> boards, and I have some questions. First, I'm not sure that this is really
> an appropriate test to run. I've found method 509.3 in Mil Std 810E (July
> 89), but nothing else. It sounds pretty tough to control. Are people
> actually conducting this test now, or are alternative assembly and chassis
> level corrosion tests being specified? What test labs are equipped to
> perform them?
>
> I would be grateful to learn from anyone who is doing this test now.
>
> Regards,
> Greg Bartlett
> Mercury Computer Systems
> Chelmsford, MA
> [log in to unmask]
>
> ***************************************************************************
> * TechNet mail list is provided as a service by IPC using SmartList v3.05 *
> ***************************************************************************
> * To unsubscribe from this list at any time, send a message to: *
> * [log in to unmask] with <subject: unsubscribe> and no text. *
> ***************************************************************************
> * If you are having a problem with the IPC TechNet forum please contact *
> * Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
> ***************************************************************************
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to: *
* [log in to unmask] with <subject: unsubscribe> and no text. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
|
|
|